Strength FAQ2 |
![]() |
![]() |
Answers To Our
Most Frequently Asked
Strength QuestionsQ: When the reporter from Inside Edition visited, what dome advantage did they zero in on? They then drove up to our corporate offices. The segment went on to show our five dome complex including the component panels being made in the factory. The next stop was to view our domes under construction in Melbourne, Florida, a 34' dome linked to a 22' garage. Also of interest was the interior metal framing and metal floor joists. The program director had previously asked us for a way to illustrate the domes' ability to withstand hurricane force winds. Short of calling up a 200 mph wind and filming the real thing, the next best option is a computer finite analysis. The computer simulated a force equal to 230 mph winds. Our dome stood rock solid. In fact, to see the movement in the dome, the deflection had to be magnified 50 times. A square structure was also modeled but it collapsed with 150 mph winds. A completed dome home was the next stop. After videoing the house and the dog dome, the reporter, Stephen Gendel, asked for an egg. While on screen he took his best shot at squeezing it to death. They departed shortly thereafter knowing that they had a good story and we can tell you with certainty, they were impressed. About a week after the program aired we got a call from the New York office. They specifically called to tell us that they had received a flood of calls from people trying to get in touch with us. For viewers to call us directly they had to figure out the city and area code on their own. One lady reported that the long distance information operator knew our number by heart. Click on Hurricane Recap to learn more. Q: What wind loads will the dome withstand? The Ai dome design has proved itself by withstanding Hurricane Andrew's 165 - 200 mph winds, hurricane Katrina's 140 mph winds, a tornado that rolled up a steel horse trailer and slammed it against the Menendez dome, four hurricanes in 2004, sub zero temperatures and heavy snow loads of the Northwest Territory of Canada, a 30" in diameter 115 foot tall hickory tree impact, a lighting strike and many other conditions since 1976. More about steel horse trailer impact: American Ingenuity warranties their concrete domes against 225 mph winds and F4 tornadoes. Since our dome kit manufacturing business started Ai has sold over 800 kits into 47 states and thirteen foreign areas. Since then American Ingenuity has not had any of our client's concrete domes have any damage due to hurricanes, earthquakes or tornadoes except for one dome during Hurricane Andrew. During Andrew a 45’ American Ingenuity Dome was impelled by a two wide steel horse trailer. A riser wall of the dome ended up with a hairline crack and a missing chunk of concrete. The dome owner caulked the crack and mixed up fiber concrete and filled the chunk and painted over the area. More about the tree impact: There was no damage to the Brack's 48' dome after winds in excess of 75 mph hit North Carolina in July of 1996. The real test came when a 115' high, 30" in diameter hickory tree was blown over and fell on their dome. The impact broke a 10" diameter branch. The tree slid off and landed on a deck post driving it and it's 16" square concrete footer 6" further into the ground. The insurance agent who inspected the damage to the deck conveyed his amazement about the dome's strength with this comment, "If that had been a frame house the tree would have ended up in the basement!" More about the lightning strike: American Ingenuity's 45' office dome withstood another one of nature's most powerful forces, a LIGHTNING STRIKE. The lightning hit the outer edge of an entryway and the only damage it did to the dome was to knock off a handful of concrete at the point of impact! A couple of our computers have not been the same since, but the cost to repair the dome did not exceed $30 in materials and labor. More about heavy snow loads: In 1995 Howard and Mary Carroll visited Robens Napolitan and Tom Kramer's dome in Idaho. Robens was enthusiastic, but Tom was not. He said "...its all HER idea, I didn't want a dome. Mary phoned them in 1996 after their basement was finished. Mary said you couldn't keep Tom quiet this time: he had nothing but wonderful things to say and had completely turned around.....ROOFS HAD COLLAPSED in their area under several feet of snow, but NOT HIS DOME! Tom's turnaround sold Mary and her husband on a dome and they bought a dome from us. Q: Has Ai performed a load test on its panel? The deflection was measured in the center and six other locations. At all the measured points a steel ruler was attached to the panel extending high enough to be visible when the panel was fully loaded with the sand. A surveyor's transit allowed us to measure the deflection. After 3,783 lbs. of sand was dumped on the panel its center had deflected less than 1/16 inch. Three days later the deflections had only increased to 3/32 inch. Our own amazement at the strength made us even more brave; so we cut through the interior plaster on the bottom of the panel. Even then the deflection was less than 3/16 inch. Ai had not expected this exceptional strength. Ai could not mound the sand any higher so we set a pallet of 40 bags of Portland Cement on top of the sand thinking, "This could do the panel in." This doubled the weight on the panel and the center deflection increased to less than 3/8 inch. The grand total deflection of less than 3/8 inch with almost four tons of weight was astonishing to us. A 120-mph wind will exert a pressure of 30 lbs. per sq.ft. on a vertical wall and a snow load exceeding 50 lbs. per sq.ft. is rare. Our panel withstood 170 lbs. per sq.ft. To read more click on Load Test. Q: The panel concrete is not that thick only 3/4", why is American Ingenuity's dome so strong? A: The panel concrete does not need to be thick because the strength comes from the steel reinforced seams are filled with concrete. The seams between the triangular and riser panels are about 5" wide and 3" deep. The steel reinforced concreted seams act like steel beams. The steel mesh transfers any stress (tree impact, horse trailer impact) all over the dome instead of containing the stress in one spot. |