Maximum Rough Opening Sizes

for Doors and/or Windows

 

Our Entryways and Dormers provide openings in the dome that accommodate conventional doors and windows that you purchase locally. The walls within these openings are built on-site to fit your choice of door and window sizes. 

 

Because the sides of the Entryways and Dormers are sloped the width of the opening decreases as the height of the opening increases. 

 

Typical heights (distance “D” from the floor to the top of the opening) are listed in the first column with the maximum available rough opening listed for each dome size. 

 

Opening sizes are listed as Width x Height.

 

 

  ENTRYWAY & HIGH PROFILE ENTRYWAY – Maximum Size Rough Opening for Doors and/or Windows.

 

D

22’

27’

30’

34’

40’

45’

48’

82”

Not Available

Not Available

99” x 82”

119” x 82”

147” x 82”

171” x 82”

186” x 82”

96"

Not Available

Not Available

86” x 96”

106” x 96”

135” x 96”

159” x 96”

173” x 96"

 

 

 

 

 

 

                    ENTRYWAY                                                                                HIGH PROFILE ENTRYWAY

 

 

  GARAGE ENTRYWAY – Maximum Garage Door Size

 

D

22’

27’

30’

34’

40’

45’

48’

84”

9’ x 7'

16’ x 7’

12’ x 7’

14’ x 7’

16’ x 7’

Not Available

Not Available

 

 

FIRST FLOOR

WINDOW and DOOR SIZES 

 

  1st FLOOR WINDOW DORMER – Replacing a Hexagon “H” Panel – Maximum Window Rough Opening

 

D

22’

27’

30’

34’

40’

45’

48’

88”

34” x 46”

53” x 46”

------

30” x 46”

45” x 46”

57” x 46”

65” x 46”

86”

36” x 44”

55” x 44”

------

32” x 44”

47” x 44”

59” x 44”

67” x 44”

84”

39” x 42”

57” x 42”

25” x 42”

34” x 42”

50” x 42”

62” x 42”

70” x 42”

82”

41” x 40”

60” x 40”

27” x 40”

37” x 40”

52” x 40”

64” x 40”

72” x 40”

80”

44” x 38”

62” x 38”

29” x 38”

40” X 38”

55” x 38”

67” x 38”

75” x 38”

 

 

  1st FLOOR WINDOW DORMER – Replacing a Pentagon “P” Panel – Maximum Window Rough Opening

 

D

22’

27’

30’

34’

40’

45’

48’

88”

Not

44” x 46”

Not

Not

30” x 46”

42” x 46”

50” x 46”

86”

Available

47” x 44”

Available

Available

33” x 44”

45” x 44”

53” x 44”

84”

Use Entryway

50” x 42”

Use Entryway

Use Entryway

36” x 42”

48” x 42”

55” x 42”

82”

Or “H” Panel

53” x 40”

Or “H” Panel

Or “H” Panel

39” x 40”

51” x 40”

58” x 40”

80”

Dormer

55” x 38”

Dormer

Dormer

41” x 38”

54” x 38”

61” x 38”

 

 

 1st FLOOR DOOR DORMER – Replacing a “H” or “P” Panel – Maximum Door Size

 

 

22’

27’

30’

34’

40’

45’

48’

H Panel :

38” x 80”

60” x 80”

24” x 80”

32” x 80”

48” x 80”

60” x 80”

68” x 80”

P Panel :

31” x 80”

53” x 80”

Not Available

Not Available

34” x 80”

46” x 80”

53” x 80”

 

                            

 

1st FLOOR                                                                                                                       

 Window Dormer                                                                                           

     

                                                           

 

 

 

 

                               1st Floor Door Dormer

 

    SECOND FLOOR

WINDOW and DOOR ROUGH OPENING SIZES 

 

   2nd FLOOR WINDOW DORMER – Replacing a “H” Panel – Maximum Window Rough Opening

 

D

22’

27’

30’

34’

40’

45’

48’

82”

 

------

 

------

34” x 52”

35” x 42”

51” x 37”

80”

2nd Floor

------

2nd Floor

------

36” x 50”

38” x 40”

54” x 35”

78”

Dormer

24” x 47” *

Dormer

------

38” x 48”

41” x 38”

57” x 33”

76”

Not

26” x 45” *

Not

22” x 50” *

40” x 46”

44” x 36”

60” x 31”

74”

Available

29” x 43” *

Available

24” x 48” *

42” x 44”

47” x 34”

63” x 29”

72”

Use

31” x 41” *

Use

26” x 46” *

------

------

------

70”

Skylight

34” x 39” *

Skylight

28” x 44” *

------

------

------

68”

 

36” x 37” *

 

30” x 42” *

------

------

------

 

Distance “D” is based on 8’ ceilings on the first floor and 2x8 second floor framing. Reduce distance “D” 2” for 2x10 framing and 4” for 2x12 framing.  

 

* First floor ceiling height for 27’ & 34’ domes with 4’ riser panels is 7’-6”.

  

 

   2nd FLOOR DOOR DORMER – Maximum Door Size

 

D

22’

27’

30’

34’

40’

45’

48’

82”

     Not      Available

   Not Available

Not Available

24” x 72”

32” x 80”

32” x 80”

48” x 80"

 

 

 

 

7’-6” 1st Fl. Ceiling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

               2nd FLOOR WINDOW DORMER            2nd FLOOR DOOR DORMER

 

 

   CUPOLA – Maximum Window Rough Opening, Five Locations

 

 

22’

27’

30’

34’

40’

45’

48’

 

Not Available

70” x 24”

60” x 24”

70” x 24”

83” x 24”

95” x 24”

102” x 24”

 

 

 

 

 

 

 

 

 

 

 

 

 

   SKYLIGHT – Triangle Shape Insulated Glass preinstalled in “H” Panels

  Base x Height

 

 

22’

27’

30’

34’

40’

45’

48’

Large:

49” x 46”

49” x 46”

------

49” x 46”

49” x 46”

49” x 46”

49” x 46”

Small:

35" x 32”

35" x 32”

35" x 32”

35" x 32”

35" x 32”

35" x 32”

35" x 32”

 

Skylights available from American Ingenuity are made of two layers of Ό” tempered safety glass with ½” sealed airspace. 

 

Since our domes are constantly being improved, specifications are subject to change without notice.

 

 

windowdoorsizes.htm 

SUITABLE STANDARD WINDOW & DOOR SIZES

FOR AMERICAN INGENUITY DOMES

 

These tables contain CALL SIZES which are the customary size identification of the window industry. Call Size is the actual window dimension, for example Call Size 3/4 x 4/6 expresses 3’-4” x 4’-6”,which converts into 40” x 54”. These tables are for Vinyl Windows with Nailing Flange, designed for Frame Construction, single or double hung. (unless otherwise noted).

 

# = Horizontal Roller or Sliding Type

* = Standard Modified Casement Window

F = French door

 

Florida and most other state’s code for Glass and Glazing requires tempered glass to be used in windows whose nearest edge is within 24” radius of a door in closed position. Tempered glass is also required for glass panes with a bottom edge less than 18” and a bottom edge greater than 36” above the floor.

 

1ST FLOOR WINDOW DORMER – Replacing a “H” Panel- Suitable Standard Window Size

           22’                 27’                 30’                 34’                 40’                 45’                 48’

      2/8 x 3/8        4/4 x 3/8             --              2/4 x 3/8        3/8 x 3/8         4/8 x 3/8#       5/0 x 3/8#

      2/8 x 3/8        4/4 x 3/8             --              2/4 x 3/8        3/8 x 3/8         4/8 x 3/8#       5/0 x 3/8#

      3/0 x 3/2        4/4 x 3/2         2/0 x 3/2       2/8 x 3/2        4/2 x 3/2#       5/0 x 3/2#       5/0 x 3/2#

      3/4 x 3/2        4/4 x 3/2         2/0 x 3/2       3/0 x 3/2        4/4 x 3/2         5/0 x 3/2#       6/0 x 3/2#

      3/8 x 3/0        4/4 x 3/0         2/4 x 3/0       3/0 x 3/0        4/4 x 3/2         5/0 x 3/2#       6/0 x 3/2#

1ST FLOOR WINDOW DORMER- Replacing a “P” Panel- Suitable Standard Window Size

           22’                27’                  30’                 34’                40’                  45’                  48’

        not             3/8 x 3/8               not                not             2/4 x 3/8         3/4 x 3/8#         3/8 x 3/8

      available       3/8 x 3/8           available          available       2/8 x 3/8         3/8 x 3/8#         4/4 x 3/8

   use entryway    3/8 x 3/2         use entryway    use entryway    3/0 x 3/2         4/0 x 3/2#         4/4 x 3/2

    or “H” Panel    4/4 x 3/2         or “H” Panel       or “H” Panel   3/0 x 3/2         4/0 x 3/2#         4/8 x 3/2#

       dormer        4/4 x 3/0            dormer             dormer        3/4 x 3/0         4/4 x 3/0           5/0 x 3/2#

1ST FLOOR DOOR DORMER- Replacing “H”or“P” Panels-Suitable Standard Door Size

                       22’          27’               30’                34’                40’                45’                  48’

“H” Panel    36”x 6/8    59”x 6/8 F      custom          30”x 6/8        36”x 6/8        59”x 6/8 F         63”x 6/8 F

“P” Panel    30”x 6/8    36”x 6/8     ot available    not available     32”x 6/8       36”x 6/8          36”x 6/8

______________________________________________________________________________________

2nd FLOOR WINDOW DORMER-Replacing “H” Panel- Suitable Standard Window Size

          22’                 27’                30’                   34’                 40’                  45’                   48’

     second floor        --               second floor           --             2/8 x 4/4         2/8 x 3/2          4/0 x 3/0#

        dormer            --                 dormer                --             3/0 x 4/0         3/0 x 3/2          4/4 x 3/0

          not            1/8 x 3/8            not                   --             3/0 x 4/0         3/4 x 3/2          3/0 x 2/8*

      available        2/0 x 3/8        available          3/0 x 3/8       3/4 x 3/8         3/8 x 3/0          3/0 x 2/4*

         use             2/4 x 3/8            use             1/8 x 3/8       3/4 x 3/8         3/0 x 2/8*        3/0 x 2/4*

      skylight          2/4 x 3/2         skylight          2/0 x 3/8            ---                   ---                    ---

                           2/8 x 3/8                              2/0 x 3/8            ---                   ---                    ---

                           2/8 x 3/0                              2/4 x 3/2            ---                   ---                    ---- 

2nd FLOOR DOOR DORMER- Suitable Standard Door Sizes

         22’                27’                30’                  34’                   40’                   45’                48’

  not available   not available   not available       custom             30”x 6/8          30”x 6/8        36”x 6/8

CUPOLA- Suitable Standard Window Sizes - Vinyl Horizontal Roller or Slider Type

         22’                27’                 30’                34’                  40’                  45’                  48’

     custom       2-2/8 x 2/0     2-2/4 x 2/0      2-2/8 x 2/0     2-3/4 x 2/0       2-3/8 x 2/0      2-4/0 x 2/0

 

Two Standard Vinyl Horizontal Roller or Slide Type Windows are needed to fill one rough window opening of a cupola. They can be installed with a Mullion in between them or custom windows can be installed.

 

 

Main


Dome Pictures

More Dome Pictures (New*)

Whaley's Spectacular Dome Photos  (New*)

 

Learn More:  Planning Kit | Video | CD | Model Dome Kit

 

Email Us | Contact Us

 

Dome Kit Prices | Specifications

Dome Building Options (New Photos*)

Shipping Costs

 

Is the A.I. Dome Home cheaper to build than a regular stick built house? (New)

 

How did the A.I. Dome perform for U.S. Dept of Energy study? (New)

 

Dome Home Financing  (New lender added July 8, 2005)

 

Floor Plans

Building Plans & Obtaining a Building Permit 

 

Frequently Asked Questions (FAQ)

 

Will the American Ingenuity Dome Leak?

 

Hurricane Recap

Tell me about the strength of the A.I.component panel (New 2005)

 

Kit Assembly Consultant

Choosing a Contractor or SubContractor

Builders and Assemblers

Pre-Construction Consultant

Insurance Companies

 

Dome Construction

Window and Door Sizes

Radial and Rib Temporary Support Systems (New Photos*)

Electrical, Plumbing, Vent Pipes, Solar, Photovotaics, Fireplaces (New Photos*)

Foundations, Pilings, Basements (New Photos*)

 

The GEO POD - Utility Dome (New Photos*)

Screen Dome Kits  (New Photos*)

Garage Dome Kits (New Photos*)

Dog Dome Kits (New Photos*)


 

Where Can I See One of Your Domes?

 

Dome Community

 

 Dome for Sale

 

Maps   Links

 

*Photos Added July 2005

 

AMERICAN INGENUITY, INC.

"Creating Intelligent Alternatives"

 

(c) Copyright 2005 All Rights Reserved. Trademarks referenced are the property of their respective owners.